SpeedSys 200 – FAQ

« Back to product page of SpeedSys 200

General FAQs

Overspeed, acceleration and underspeed. All of these can be simultaneously configured to all four relays. This allows for maximum configuration flexibility.

By periodically testing (parts of) a system the PFD (probability of failure on demand) is reduced, leading to higher reliability. SpeedSys 200 allows for proof testing of tailing equipment by switching its relays through the software. The transmitter itself has a typical proof test interval of

The sensor cable lengths are not defined by the SpeedSys transmitter, but by the sensor and application specifics.

No, the sensor input circuitry is ATEX certified (zone 0 & 20). This gives the hardware the advanced ability to monitor the sensors and detect sensor failure. With external barriers this is not possible.

The configuration of the commissioned unit needs to be uploaded to the replacement unit. After that the units can be swapped.

The SpeedSys modules are mounted on a DIN rail, but a 19